Hình ảnh có thể mang tính chất minh họa.
Xem thông số kỹ thuật để biết chi tiết sản phẩm.
P51-15-G-Y-I36-4.5V-000-000

P51-15-G-Y-I36-4.5V-000-000

Product Category: Electronic Component

Use: The P51-15-G-Y-I36-4.5V-000-000 is a precision pressure sensor designed for use in various industrial and commercial applications. It is commonly used to measure and monitor pressure in systems such as HVAC, pneumatic controls, and hydraulic systems.

Characteristics: This sensor is known for its high accuracy, reliability, and durability. It is designed to operate effectively in harsh environments and can withstand extreme temperatures and pressures. The package includes the sensor itself along with necessary mounting hardware and connectors.

Essence: The essence of the P51-15-G-Y-I36-4.5V-000-000 lies in its ability to provide accurate and consistent pressure measurements, contributing to the efficient operation and maintenance of various systems.

Packaging/Quantity: The sensor is typically packaged individually and comes with detailed installation and usage instructions. The quantity per package may vary based on the supplier and customer requirements.


Specifications

  • Pressure Range: 0-15 psi
  • Output: 4.5V
  • Electrical Connection: 3-wire
  • Operating Temperature: -40°C to 125°C
  • Pressure Type: Gauge
  • Accuracy: ±1% full scale

Detailed Pin Configuration

The P51-15-G-Y-I36-4.5V-000-000 features a 3-pin electrical connection: 1. Vcc (Power Supply) 2. GND (Ground) 3. Signal Output


Functional Features

  • High accuracy and repeatability
  • Robust construction for harsh environments
  • Wide operating temperature range
  • Long-term stability
  • Low power consumption

Advantages and Disadvantages

Advantages: - Accurate and reliable pressure measurements - Suitable for diverse industrial applications - Durable construction for long-term use - Low power consumption

Disadvantages: - Limited pressure range - May require calibration for specific applications


Working Principles

The P51-15-G-Y-I36-4.5V-000-000 operates on the principle of piezoresistive sensing. When pressure is applied, the internal diaphragm deflects, causing a change in resistance which is then converted into an electrical signal proportional to the applied pressure.


Detailed Application Field Plans

The P51-15-G-Y-I36-4.5V-000-000 is suitable for a wide range of applications including: - HVAC systems - Pneumatic controls - Hydraulic systems - Industrial automation - Process control


Detailed and Complete Alternative Models

  • P51-10-A-P-I12-5V-000-000
  • P51-20-B-R-I24-3.3V-000-000
  • P51-30-C-Y-I48-5V-000-000

These alternative models offer varying pressure ranges, output voltages, and package configurations to suit different application requirements.


This comprehensive entry provides a detailed overview of the P51-15-G-Y-I36-4.5V-000-000 precision pressure sensor, covering its specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Liệt kê 10 câu hỏi và câu trả lời thường gặp liên quan đến ứng dụng P51-15-G-Y-I36-4.5V-000-000 trong giải pháp kỹ thuật

  1. What is the application of P51-15-G-Y-I36-4.5V-000-000?

    • P51-15-G-Y-I36-4.5V-000-000 is a pressure transducer commonly used in industrial and technical solutions to measure and monitor fluid pressures.
  2. How does P51-15-G-Y-I36-4.5V-000-000 work?

    • This pressure transducer works by converting the mechanical pressure applied to it into an electrical signal, which can then be interpreted and utilized in various technical applications.
  3. What are the typical operating conditions for P51-15-G-Y-I36-4.5V-000-000?

    • The typical operating conditions for this pressure transducer include a temperature range of -40°C to 125°C and a pressure range suitable for the specific model.
  4. Can P51-15-G-Y-I36-4.5V-000-000 be used in hazardous environments?

    • Yes, there are models of P51-15-G-Y-I36-4.5V-000-000 that are designed to be intrinsically safe and suitable for use in hazardous environments.
  5. What are the output options for P51-15-G-Y-I36-4.5V-000-000?

    • The output options may include analog voltage or current signals, digital communication protocols such as CANbus or Modbus, or a combination of these, depending on the specific model.
  6. Is P51-15-G-Y-I36-4.5V-000-000 suitable for high-pressure applications?

    • Yes, there are versions of P51-15-G-Y-I36-4.5V-000-000 designed to withstand high-pressure environments, but it's important to select the appropriate model based on the specific requirements.
  7. What are the calibration and maintenance requirements for P51-15-G-Y-I36-4.5V-000-000?

    • Calibration and maintenance requirements may vary by model, but generally, periodic calibration and inspection are recommended to ensure accurate and reliable performance.
  8. Can P51-15-G-Y-I36-4.5V-000-000 be integrated with control systems or data acquisition systems?

    • Yes, this pressure transducer can typically be integrated with various control systems and data acquisition systems using the available output options and communication protocols.
  9. Are there any special considerations for installation of P51-15-G-Y-I36-4.5V-000-000?

    • Proper mounting, sealing, and electrical connections are important considerations for the installation of P51-15-G-Y-I36-4.5V-000-000 to ensure accurate and reliable operation.
  10. Where can I find technical specifications and documentation for P51-15-G-Y-I36-4.5V-000-000?

    • Technical specifications and documentation for P51-15-G-Y-I36-4.5V-000-000 can typically be obtained from the manufacturer's website, product datasheets, or through authorized distributors.